Pro Clima SOLITEX FRONTA QUATTRO - Wall lin­ing mem­brane - 75m² - 12933
Pro Clima FRONTA QUATTRO
Pro Clima SOLITEX FRONTA QUATTRO - Wall lin­ing mem­brane - 75m² - 12933
Pro Clima FRONTA QUATTRO
Previous keyboard_arrow_left
Next keyboard_arrow_right
zoom_in
  • -10%

Pro Clima SOLITEX FRONTA QUATTRO | Wall lin­ing mem­brane - 75m² | 12933

€338.40 €376.00 Save 10%
  • In stock Delivery time: 1 to 3 working days
  • Free shipping in the Benelux from €50
  • Secure online payment or on account

Pro Clima SOLITEX FRONTA QUATTRO - Wall lin­ing mem­brane

SOLI­TEX FRONTA QUAT­TRO per­man­ently pro­tects the in­su­la­tion from wind and rain. For use with closed and open façades.

Width: 1,5m  /  Length: 50m  /  Surface: 75m²

Item number Pro Clima: 12933

SOLITEX FRONTA QUATTRO

3-ply wall lin­ing mem­brane with mono­lith­ic TEEE func­tion­al mem­brane, suit­able for open join­ted and closed façades.

System SOLITEX FRONTA QUATTRO
 

Advantages

  • Highly dif­fu­sion-per­meable, but with max­im­um res­ist­ance to driv­ing rain
  • Op­tim­um dry­ing con­di­tions for wall struc­tures: non-por­ous TEEE func­tion­al mem­brane act­ively trans­ports mois­ture out­wards
  • Black fleece and black print pre­vent the mem­brane show­ing through open join­ted façades
  • Max­im­um age­ing res­ist­ance and thermal sta­bil­ity thanks to the TEEE mem­brane
  • 6 months of out­door ex­pos­ure

Application

SOLI­TEX FRONTA QUAT­TRO per­man­ently pro­tects the in­su­la­tion from wind and rain. For use with closed and open façades (open join­ted façades, up to 35 mm (1 3/8") gap width – board­ing width = min. 3 x gap width) in ac­cord­ance with in­stall­a­tion guidelines.

Technical specs

  Material
Protective and covering fleece Polypropylene microfibre
Membrane monolithic TEEE
Attribute Norm Value
Colour black, Print: black
Surface weight EN 1849-2 180 ±5 g/m² ; 0.59 ±0.02 oz/ft²
Thickness EN 1849-2 0.60 ±0.10 mm ; 24 ±4 mils
Water vapour resistance factor µ EN ISO 12572 80
sd-value EN ISO 12572 0.05 ±0.02 m
g-value 0.25 ±0.1 MN·s/g
Vapor permeance ASTM E 96 65.6 US perms
Reaction to fire EN 13501-1 E
Exposure time 6 months
Water column EN 20811 10 000 mm ; 32' 10"
Water resistance un-/aged* EN 1928 W1 / W1
Tensile strength MD/CD EN 12311-1 290 ±20 N/5 cm / 220 ±20 N/5 cm ; 33 ±2 lb/in / 25 ±2 lb/in
Tensile strength MD/CD aged* EN 12311-1 200 ±20 N/5 cm / 135 ±20 N/5 cm ; 23 ±2 lb/in / 15 ±2 lb/in
Elongation MD/CD EN 12311-1 50 ±20 % / 70 ±20 %
Elongation MD/CD aged* EN 12311-1 30 ±20 % / 40 ±20 %
Nail tear resistance MD/CD EN 12310-1 250 ±30 N / 240 ±30 N ; 56 ±7 lbf / 54 ±7 lbf
*) Artificial ageing by long term EN 1297 / EN 1296 passed (for walls with open joints)
Flexibility at low temperature EN 1109 -40 °C ; -40 °F
Temperature resistance -40 °C to +100 °C ; -40 °F to 212 °F
Thermal conductivity 0.17 W/(m·K) ; 1.18 BTU·in/(h·ft²·F)
CE labelling EN 13859-2 available

General conditions

SOLITEX FRONTA QUATTRO membranes must be laid with the printed side facing outwards. They can be laid flat either at right angles to, or along the sub-structure without sagging. Horizontal installation is preferable with regard to water tightness during the construction phase.

When using behind open jointed façades the gaps must not be more than 35 mm (1 3/8"). The width of the boarding: min. 3 x gap width.
The distance between the façade and the membrane must be at least 20 mm (1").

The membrane must not be secured in areas where water collectively drains off.

Additional measures during the building phase (e.g. covering with tarpaulin) should be taken in the case of occupied buildings or buildings that need particular protection. Covering with tarpaulin should also be considered in the case of extended interruptions to work.